diff options
author | Jörg Frings-Fürst <debian@jff-webhosting.net> | 2021-05-18 07:43:35 +0200 |
---|---|---|
committer | Jörg Frings-Fürst <debian@jff-webhosting.net> | 2021-05-18 07:43:35 +0200 |
commit | 9f8889f928ce86ba4a78659d378c6ba29bc9f735 (patch) | |
tree | c9567cb0d015b68ce3da8d03472b6443f1cb1ca9 /doc/sane-plustek.man | |
parent | 446e9454b8cbe5b689149415d11d36e88442ca88 (diff) | |
parent | 154785ab2d5df7ddc8c2cf813b773c340e5e2aea (diff) |
Merge branch 'release/debian/1.0.32-1'debian/1.0.32-1
Diffstat (limited to 'doc/sane-plustek.man')
-rw-r--r-- | doc/sane-plustek.man | 44 |
1 files changed, 29 insertions, 15 deletions
diff --git a/doc/sane-plustek.man b/doc/sane-plustek.man index 2df85b6..c043072 100644 --- a/doc/sane-plustek.man +++ b/doc/sane-plustek.man @@ -11,7 +11,7 @@ provides access to USB flatbed scanners based on National Semiconductor Merlin chipsets (LM9831, 9832 and 9833). If you're looking for parallel-port support for Plustek scanner please refer to the -.B sane\-plustek_pp +.BR sane\-plustek_pp (5) backend. .SH "SUPPORTED DEVICES" @@ -184,12 +184,12 @@ Strobe XP100 LM9833 600x1200dpi 48bit 512Kb 0x0427 .SH "OTHER PLUSTEK SCANNERS" For parallelport device support see the -.B plustek_pp +.BR sane\-plustek_pp (5) backend. .br The SCSI scanner OpticPro 19200S is a rebadged Artec AM12S scanner and is supported by the -.B Artec +.BR sane\-artec (5) backend. .br Only the National Semiconductor LM983[1/2/] based devices of Plustek @@ -210,13 +210,14 @@ UT12 P98003 u12 .fi .ft R For a more complete and up to date list see: -.B http://www.sane\-project.org/sane\-supported\-devices.html +.IR http://www.sane\-project.org/sane\-supported\-devices.html . .SH "CONFIGURATION" To use your scanner with this backend, you need at least two entries in the configuration file .I @CONFIGDIR@/plustek.conf .RS +.PP .I [usb] vendor-id product-id .br .I device /dev/usbscanner @@ -279,7 +280,7 @@ m/PID | 0x1000 | 0x1001 option invertNegatives b .RS .I b -0 --> do not invert the picture during negativ scans, +0 --> do not invert the picture during negative scans, .br 1 --> invert picture .RE @@ -289,7 +290,9 @@ option cacheCalData b .I b 0 --> do not save calibration results, .br -1 --> save results of calibration in ~/.sane/ directory +1 --> save results of calibration in +.I ~/.sane/ +directory .RE .PP option altCalibration b @@ -415,9 +418,9 @@ See the plustek.conf file for examples. You have to make sure, that the USB subsystem is loaded correctly and you have access to the device-node. For more details see -.B sane\-usb (5) +.BR sane\-usb (5) manpage. You might use -.B sane\-find\-scanner +.BR sane\-find\-scanner (1) to check that you have access to your device. .PP .B Note: @@ -445,13 +448,19 @@ contain the configuration file. Under UNIX, the directories are separated by a colon (`:'), under OS/2, they are separated by a semi-colon (`;'). If this variable is not set, the configuration file is searched in two default directories: first, the current working -directory (".") and then in @CONFIGDIR@. If the value of the +directory (".") and then in +.IR @CONFIGDIR@ . +If the value of the environment variable ends with the directory separator character, then the default directories are searched after the explicitly specified directories. For example, setting .B SANE_CONFIG_DIR -to "/tmp/config:" would result in directories "tmp/config", ".", and -"@CONFIGDIR@" being searched (in this order). +to "/tmp/config:" would result in directories +.IR "tmp/config" , +.IR "." , +and +.I "@CONFIGDIR@" +being searched (in this order). .TP .B SANE_DEBUG_PLUSTEK If the library was compiled with debug support enabled, this @@ -466,6 +475,9 @@ export SANE_DEBUG_PLUSTEK=10 .BR sane\-usb (5), .BR sane\-u12 (5), .BR sane\-gt68xx (5), +.BR sane-\mustek_pp (5), +.BR sane\-find\-scanner (1), +.BR scanimage (1), .br .I @DOCDIR@/plustek/Plustek-USB.changes @@ -478,14 +490,16 @@ Additional info and hints can be obtained from our .br Mailing-List archive at: .br -.B http://www.sane\-project.org/mailing\-lists.html +.I http://www.sane\-project.org/mailing\-lists.html .PP To obtain debug messages from the backend, please set the environment-variable -.I SANE_DEBUG_PLUSTEK -before calling your favorite scan-frontend (i.e. scanimage). +.B SANE_DEBUG_PLUSTEK +before calling your favorite scan-frontend (i.e. +.BR scanimage (1)), i.e.: + .br -.B i.e.: export SANE_DEBUG_PLUSTEK=20 ; scanimage +.I export SANE_DEBUG_PLUSTEK=20 ; scanimage .PP The value controls the verbosity of the backend. Please note, that values greater than 24 force the backend to output raw data files, |